DEFENSE TECHNOLOGY OF AMERICA -- BLAST AGENT-CS
MATERIAL SAFETY DATA SHEET
NSN: 137500N066482
Manufacturer's CAGE: 0WVH8
Part No. Indicator: A
Part Number/Trade Name: BLAST AGENT-CS
===========================================================================
General Information
===========================================================================
Company's Name: DEFENSE TECHNOLOGY CORP OF AMERICA
Company's P. O. Box: 240
Company's City: CASPER
Company's State: WY
Company's Country: US
Company's Zip Code: 82602
Company's Emerg Ph #: 800-424-9300 (CHEMTREC)
Company's Info Ph #: 800-733-3832
Record No. For Safety Entry: 001
Tot Safety Entries This Stk#: 001
Status: SMJ
Date MSDS Prepared: 23SEP93
Safety Data Review Date: 14NOV95
MSDS Serial Number: BZRYY
Hazard Characteristic Code: NK
===========================================================================
Ingredients/Identity Information
===========================================================================
Proprietary: NO
Ingredient: MAGNESIUM OXIDE
Ingredient Sequence Number: 01
NIOSH (RTECS) Number: OM3850000
CAS Number: 1309-48-4
OSHA PEL: 15 MG/M3 PARTICULATE
ACGIH TLV: 10 MG/M3; FUME
-------------------------------------
Proprietary: NO
Ingredient: MALONONITRILE, O-CHLOROBENZYL-; (O-CHLOROBENZALMALONONITRILE)
Ingredient Sequence Number: 02
NIOSH (RTECS) Number: 003660000
CAS Number: 40915-55-7
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
===========================================================================
Physical/Chemical Characteristics
===========================================================================
Appearance And Odor: WHITE POWDER.
Boiling Point: N/A
Melting Point: N/A
Vapor Pressure (MM Hg/70 F): N/A
Vapor Density (Air=1): N/A
Specific Gravity: >1 (H*2O=1)
Evaporation Rate And Ref: NOT KNOWN
Solubility In Water: NO
===========================================================================
Fire and Explosion Hazard Data
===========================================================================
Flash Point: N/A
Lower Explosive Limit: N/A
Upper Explosive Limit: N/A
Extinguishing Media: NOT APPLICABLE.
Special Fire Fighting Proc: USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire And Expl Hazrds: NON-COMBUSTIBLE.
===========================================================================
Reactivity Data
===========================================================================
Stability: YES
Cond To Avoid (Stability): NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: REACTS VIOLENTLY WITH CHLORINE TRIFLUORIDE AND
PHOSPHOROUS PENTACHLORIDE.
Hazardous Decomp Products: CARBON MONOXIDE, CARBON DIOXIDE, TOXIC FUMES.
Hazardous Poly Occur: NO
Conditions To Avoid (Poly): NOT RELEVANT.
===========================================================================
Health Hazard Data
===========================================================================
LD50-LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry - Inhalation: YES
Route Of Entry - Skin: YES
Route Of Entry - Ingestion: YES
Health Haz Acute And Chronic: ACUTE:EXCESSIVE TEARING AND IRRITATION OF
THE MUCOUS MEMBRANES. CHRONIC:NONE LISTED BY MANUFACTURER.
Carcinogenicity - NTP: NO
Carcinogenicity - IARC: NO
Carcinogenicity - OSHA: NO
Explanation Carcinogenicity: NOT RELEVANT.
Signs/Symptoms Of Overexp: SEE HEALTH HAZARDS.
Med Cond Aggravated By Exp: DERMATITIS.
Emergency/First Aid Proc: CONTACT PHYSICIAN FOR FOLLOW UP AFTER FIRST AID.
INHAL:REMOVE TO FRESH AIR, GIVE OXYGEN IF NECESSARY. EYE:FLUSH WITH WATER
FOR @ LEAST 15 MINUTES. SKIN:REMOVE CONTAMINATED CLOTHING; WASH WITH SOAP
AND WATER. INGEST:CONTACT PHYSICIAN.
===========================================================================
Precautions for Safe Handling and Use
===========================================================================
Steps If Matl Released/Spill: PICK UP SPILLED MATERIAL AND CONTAINERIZE
WHILE WEARING ADEQUATE NIOSH/MSHA APPRVD RESPIRATOR AND PROTECTIVE
CLOTHING.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Method: INCINERATE. FEDERAL, STATE AND LOCAL LAWS TAKE
PRECEDENCE.
Precautions-Handling/Storing: STORE IN A COOL, DRY AREA AWAY FROM HEAT
SOURCE, SPARKS OR OPEN FLAMES.
Other Precautions: NONE.
===========================================================================
Control Measures
===========================================================================
Respiratory Protection: NIOSH/MSHA APPRVD MASK FOR SUBMICRON PARTICLES AND
TEAR GAS OR NIOSH/MSHA APPRVD SELF-CONTAINED BREATHING APPARATUS.
Ventilation: LOCAL EXHAUST AND MECHANICAL (GENERAL).
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: TYVEX COVERALLS OR SIMILAR TO AVOID SKIN
CONTACT. ANSI APPRVD EMERGENCY EYE WASH & DELUGE SHOWER (FP N).
Work Hygienic Practices: WASH WITH SOAP AND WATER. WASH CONTAMINATED
CLOTHES BEFORE RE-USE.
Suppl. Safety & Health Data: NONE SPECIFIED BY MANUFACTURER.
===========================================================================
Transportation Data
===========================================================================
===========================================================================
Disposal Data
===========================================================================
===========================================================================
Label Data
===========================================================================
Label Required: YES
Technical Review Date: 14NOV95
Label Date: 14NOV95
Label Status: G
Common Name: BLAST AGENT-CS
Chronic Hazard: NO
Signal Word: CAUTION!
Acute Health Hazard-Slight: X
Contact Hazard-Slight: X
Fire Hazard-None: X
Reactivity Hazard-None: X
Special Hazard Precautions: ACUTE:EXCESSIVE TEARING AND IRRITATION OF THE
MUCOUS MEMBRANES. CHRONIC:NONE LISTED BY MANUFACTURER.
Protect Eye: Y
Protect Skin: Y
Protect Respiratory: Y
Label Name: DEFENSE TECHNOLOGY CORP OF AMERICA
Label P.O. Box: 240
Label City: CASPER
Label State: WY
Label Zip Code: 82602
Label Country: US
Label Emergency Number: 800-424-9300 (CHEMTREC)